Cable Quad EAP-CC-2S-P-R

Submitted by Anonymous (not verified) on

Cables with 7, 12 and 19 star quads, Ø1,2mm foam-skin PE-insulated conductors and stranded in layers to build the core, which is jelly filled. The cable core is then protected with a double PE sheath. To protect these cables against humidity, electromagnetic interferences and mechanical efforts, they have an aluminium shield, a copper wire screen and a galvanized steel armour. Paper and plastic tapes complete the cable formation. To be installed in ducts or direct buried According to MÁV P-2518/2002 technical specification.

Cable Quad EAP-CC-P-R

Submitted by Anonymous (not verified) on

Cables from 1 to 50 star quads, conductors with diameter 0.8mm and foam skin-PE-insulated, stranded into 5-quad units to build the core, which is jelly filled. The filled cable core is then protected with a double PE sheath with a copper wire screen between them. To be installed in ducts or direct buried Generally according to MÁV Technical Specifications: P-2518_2002

Cable Multiconductor EAPA2SP

Submitted by Anonymous (not verified) on

Cables from 2 to 91 copper conductors with diameter 1.0mm, 1.5mm or 2.5mm and polyethylene insulated, stranded in layers, with a special designed sheath to protect the cable for external inductive interferences. To be installed in ducts or direct buried. Generally according to MÁV technical specifications: P-12440_P3196_P-682_P6014

Cable AJ-2YOF(L)2YDB2Y_H115-H145 RK400

Submitted by Anonymous (not verified) on

Cables from 1 to 200 conductors of 0.9, 1.4 and 1.8 mm, polyethylene insulated. Conductors are stranded in layers to form the core which is filled with a low dielectric compound to prevent water penetration and then is protected by an anti-inductive (L)2YDB2Y sheath with reduction factor according to customer’s requirements. They are used as control cables up to 100 Hz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant.

Cable A-2YOF(L)2YV_H115-H145

Submitted by Anonymous (not verified) on

Cables from 1 to 120 conductors of 0.9, 1.4 and 1.8 mm, polyethylene insulated. Conductors are stranded in layers to form the core which is then protected by a 2YV sheath. They are used as control cables up to 100 Hz signals, especially in rail infrastructures laid in ducts. Generally according to DB AG 416.0116 and DB AG 416.0114

Cable HP_AJ-2Y(L)2YDB2Y_H45 RK400

Submitted by Anonymous (not verified) on

Cables from 1 to 40 quads of 0.9 or 1.4 mm, polyethylene insulated. Quads are stranded in layers to form the core (dry core) which is then protected by an anti inductive (L)2YBD2Y sheath with reduction factor according to customer’s requirements. They are used as control cables up to 90 kHz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant. Generally according to DB AG 416.0116 and DB AG 416.0115

Cable A-2Y(L)2YV_H45

Submitted by Anonymous (not verified) on

Cables from 1 to 40 quads of 0.9 or 1.4 mm, polyethylene insulated. Quads are stranded in layers to form the core which is protected by a 2YV sheath. They are used as control cables up to 90 kHz signals, especially in rail infrastructures laid in ducts. Generally according to DB AG 416.0116 and DB AG 416.0115

Cable ZUG-S

Submitted by Anonymous (not verified) on

Flexible electric cables intended for the interior equipment of signaling circuits, 6 and 12 pairs. Tinned copper conductors, PVC insulated. Cabling in pairs and assembly in concentric layers. Outer sheath in black PVC, without armour. These cables are flame retardant and mineral oil resistant.

Cable ZC03

Submitted by Anonymous (not verified) on

Railway signalling cable of 8 pairs (4 quads). Copper conductor of 1 mm2, insulated with solid coloured polyethylene. Stranded in quads. Shielded with a corrugated copper tape and armoured with two steel tapes helically applied. PVC unleaded outer sheath. To be installed in conduit or buried along routes electrified at 25000 volts. Generally according to SNCF CT-445 and EN 50265-2-1

Cable ZPFU

Submitted by Anonymous (not verified) on

Railway signalling cables from 1 to 28 pairs. Copper conductor of 1 mm2, insulated with solid polyethylene and stranded in pairs. Armoured with two steel tapes applied helically. PVC unleaded outer sheath. This cable is flame retardant and resistant to mineral oils.Generally according to SNCF CT-445 and EN 50265-2-1