Antenna, and coaxial radiant cables

Submitted by admin on

Indoor and outdoor antenna solutions, flexible and superflexible coaxial feeders, leakage cable solutions for underground applications with composite and dedicated 5G cables, bridges for transmitting signal and radio frequency with various types of connectors and lengths. 

Thanks to its broad portfolio, Cablescom can provide a complete E2E solution for wireless and fixed broadband radio access, helping our customers update their cellular sites. 

ESG

Submitted by admin on

At Cablescom, we see sustainability as a fundamental part of our business strategy, one that is part of a complete, goal-oriented plan in which we incorporate social, environmental and government considerations in all our operations, decision-making and business culture.

ECOVADIS

Submitted by admin on

Cablescom is assessed annually on sustainability by ECOVADIS. In 2023, we received the EcoVadis Gold Medal with an overall score of 74/100 and a percentile of 97%. This means that our score is equal to or higher than 97% of all companies assessed. We take great pride in joining the scant 5% (out of more than 100K assessed) of companies awarded with such recognition.

GREENHOUSE GAS STRATEGY

Submitted by admin on

As part of the Hengtong Group, a leading company in its sector, Cablescom works actively to provide quality products and services, always taking into consideration to current state of the environment. The company is committed to a circular economy model and enforcing due action oriented to the use of resources and prioritizing the reuse of material whose nature prevents it from being returned to the environment.

ENVIRONMENTAL PRODUCT DECLARATION (EPD)

Submitted by admin on

At Cablescom we are committed to a model of sustainability and growth through a circular economy.

To achieve this, factual knowledge on the environmental impact of our organisation, its processes and products, is essential. In line with our strategic objectives, we have worked on the implementation of the necessary tools to make information available to our customers on the environmental performance of our products.

Cable AJ-2YOF(L)2YDB2Y_H115-H145 RK600

Submitted by admin on

Cables from 1 to 200 conductors of 0.9, 1.4 and 1.8 mm, polyethylene insulated. Conductors are stranded in layers to form the core which is filled with a low dielectric compound to prevent water penetration and then is protected by an anti-inductive (L)2YDB2Y sheath with reduction factor according to customer’s requirements. They are used as control cables up to 100 Hz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant.

Cable AJ-2YOF(L)2YDB2Y_H115-H145 RK500

Submitted by admin on

Cables from 1 to 200 conductors of 0.9, 1.4 and 1.8 mm, polyethylene insulated. Conductors are stranded in layers to form the core which is filled with a low dielectric compound to prevent water penetration and then is protected by an anti-inductive (L)2YDB2Y sheath with reduction factor according to customer’s requirements. They are used as control cables up to 100 Hz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant.

Cable AJ-2Y(L)2YDB2Y_H45 RK600

Submitted by admin on

Cables from 1 to 40 quads of 0.9 or 1.4 mm, polyethylene insulated. Quads are stranded in layers to form the core (dry core) which is then protected by an anti inductive (L)2YBD2Y sheath with reduction factor according to customer’s requirements. They are used as control cables up to 90 kHz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant. Generally according to DB AG 416.0116 and DB AG 416.0115

Cable AJ-2Y(L)2YDB2Y_H45 RK500

Submitted by admin on

Cables from 1 to 40 quads of 0.9 or 1.4 mm, polyethylene insulated. Quads are stranded in layers to form the core (dry core) which is then protected by an anti inductive (L)2YBD2Y sheath with reduction factor according to customer’s requirements. They are used as control cables up to 90 kHz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant. Generally according to DB AG 416.0116 and DB AG 416.0115