ADSS Multitube anti-shooting

PKCP
FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm)
8 4+2 220 17
16 4+2 220 17
24 6+0 220 17
32 4+2 220 17
48 6+0 220 17
64 8+0 260 19
FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm) Maximum tensile strength MAT (N) Impact resistence Curvature Crush resistance Thermal cycle Water penetration Jacket Thickness / FRP Diam (mm)
8 4+2 220 17 4000 N 5 J r =15d mm (r ≥ 250 mm) 2000N (∆α<0.05 dB) -20ºC / +60ºC (∆α<0.05 dB) LPwater ≤ 3 m (24 hours)
16 4+2 220 17 4000 N 5 J r =15d mm (r ≥ 250 mm) 2000N (∆α<0.05 dB) -20ºC / +60ºC (∆α<0.05 dB) LPwater ≤ 3 m (24 hours)
24 6+0 220 17 4000 N 5 J r =15d mm (r ≥ 250 mm) 2000N (∆α<0.05 dB) -20ºC / +60ºC (∆α<0.05 dB) LPwater ≤ 3 m (24 hours)
32 4+2 220 17 4000 N 5 J r =15d mm (r ≥ 250 mm) 2000N (∆α<0.05 dB) -20ºC / +60ºC (∆α<0.05 dB) LPwater ≤ 3 m (24 hours)
48 6+0 220 17 4000 N 5 J r =15d mm (r ≥ 250 mm) 2000N (∆α<0.05 dB) -20ºC / +60ºC (∆α<0.05 dB) LPwater ≤ 3 m (24 hours)
64 8+0 260 19 4300 N 5 J r =15d mm (r ≥ 250 mm) 2000N (∆α<0.05 dB) -20ºC / +60ºC (∆α<0.05 dB) LPwater ≤ 3 m (24 hours)

Referencia: PKCP (68.HP_PKCP_i)

Description

Double PE sheathed fibre-optic cables with aramid yarns and tapes to make the cable resistant against shootings.

This cable is recommended for self-supporting aerial installation with maximum spans of 80 m, in areas with risk of being hit by buckshot.