Cable AJ-2Y(L)2YDB2Y_H45 RK500

Diameter of conductors (mm) Number of conductors Nominal Weight (kg/km) Nominal OD (mm)
0.9 1x4 15.5 514
0.9 3x4 20.5 785
0.9 5x4 22.9 945
0.9 7x4 24.2 1069
0.9 10x4 28.9 1356
0.9 14x4 31.2 1592
0.9 20x4 33.7 1880
0.9 40x4 43.4 2918
1.4 1x4 17.7 649
1.4 3x4 24.7 1080
1.4 5x4 28.3 1378
1.4 7x4 30.4 1619
1.4 10x4 37.3 2123
1.4 14x4 40.3 2551
Diameter of conductors (mm) Number of conductors Maximum allowable radius Operating temperature range Installation temperature range
0.9 1x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 3x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 5x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 7x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 10x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 14x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 20x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 40x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 1x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 3x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 5x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 7x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 10x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 14x4 Un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C

Reference: HP_AJ-2Y(L)2YDB2Y_H45 (16. HP_AJ-2Y(L)2YDB2Y_H45_i) RK500

Description

Cables from 1 to 40 quads of 0.9 or 1.4 mm, polyethylene insulated. Quads are stranded in layers to form the core (dry core) which is then protected by an anti inductive (L)2YBD2Y sheath with reduction factor according to customer’s requirements. They are used as control cables up to 90 kHz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant. Generally according to DB AG 416.0116 and DB AG 416.0115

They are used as control cables up to 90 kHz signals, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried.