Diameter of conductors (mm) | Number of conductors | Nominal Weight (kg/km) | Nominal OD (mm) |
---|---|---|---|
1.4 | 2x1 | 12,6 | 244 |
1.4 | 4x1 | 13,7 | 264 |
1.4 | 7x1 | 15,2 | 343 |
1.4 | 9x1 | 16,5 | 402 |
1.4 | 12x1 | 17,9 | 476 |
1.4 | 19x1 | 19,8 | 631 |
1.4 | 27x1 | 22,7 | 821 |
1.4 | 37x1 | 25,1 | 1034 |
1.4 | 48x1 | 28,1 | 1279 |
1.4 | 61x1 | 30,2 | 1537 |
Diameter of conductors (mm) | Number of conductors | Maximum allowable radius | Operating temperature range | Installation temperature range |
---|---|---|---|---|
1.4 | 2x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 4x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 7x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 9x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 12x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 19x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 27x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 37x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 48x1 | 15 x Ø cable | -25° C / +75° C | |
1.4 | 61x1 | 15 x Ø cable | -25° C / +75° C |
Reference: EA470H0 (45. HP_EA470H0_e)
Description
Cables from 2 to 61 conductors. Copper conductor of 1,4mm section insulated with polyethylene. Conductors are stranded in layers to form the core, core that is protected with a EAPSSP type sheath. Cable protected against rodents.
They are used in signaling railway applications. Recommended for installation in ducts or buried.