Cable A-2Y(L)2YB2Y_H45

A-2Y(L)2YB2Y_H45
Diameter of conductors (mm) Number of conductors Nominal Weight (kg/km) Nominal OD (mm)
0.9 1x4 12,3 177
0.9 3x4 17,3 320
0.9 5x4 19,7 420
0.9 7x4 21 506
0.9 10x4 25.5 675
0.9 14x4 27.4 828
0.9 20x4 30.1 1060
0.9 30x4 36.7 1492
0.9 40x4 39.2 1840
1.4 1x4 14.2 249
1.4 3x4 21.5 510
1.4 5x4 24.9 707
1.4 7x4 27 892
1.4 10x4 33.9 1241
1.4 14x4 36.5 1570
1.4 20x4 40.2 2060
1.4 30x4 49.5 2953
1.4 40x4 53.2 3729
Diameter of conductors (mm) Number of conductors Maximum allowable radius Operating temperature range Installation temperature range
0.9 1x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 3x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 5x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 7x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 10x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 14x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 20x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 30x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
0.9 40x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 1x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 3x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 5x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 7x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 10x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 14x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 20x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 30x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C
1.4 40x4 un-armoured 7.5 x Ø cable armoured 10 x Ø cable -40° C to +60° C -10° C to +60° C

Reference: A-2Y(L)2YB2Y_H45 (01.HP_A-2Y(L)2YB2Y_H45_e)

Description

Cables from 1 to 40 quads of 0.9 or 1.4 mm, polyethylene insulated. Quads are stranded in layers to form the core which is then protected by a (L)2YB2Y anti rodent sheath. For installation in ducts or directly buried. Generally according to DB AG 416.0116 and DB AG 416.0115

They are used as control cables up to 90 kHz signals, especially in rail infrastructures, when protection is required against rodents.