Cable A-2Y(L)2YB2Y_H45
Diameter of conductors (mm) | Number of conductors | Nominal Weight (kg/km) | Nominal OD (mm) |
---|---|---|---|
0.9 | 1x4 | 12,3 | 177 |
0.9 | 3x4 | 17,3 | 320 |
0.9 | 5x4 | 19,7 | 420 |
0.9 | 7x4 | 21 | 506 |
0.9 | 10x4 | 25.5 | 675 |
0.9 | 14x4 | 27.4 | 828 |
0.9 | 20x4 | 30.1 | 1060 |
0.9 | 30x4 | 36.7 | 1492 |
0.9 | 40x4 | 39.2 | 1840 |
1.4 | 1x4 | 14.2 | 249 |
1.4 | 3x4 | 21.5 | 510 |
1.4 | 5x4 | 24.9 | 707 |
1.4 | 7x4 | 27 | 892 |
1.4 | 10x4 | 33.9 | 1241 |
1.4 | 14x4 | 36.5 | 1570 |
1.4 | 20x4 | 40.2 | 2060 |
1.4 | 30x4 | 49.5 | 2953 |
1.4 | 40x4 | 53.2 | 3729 |
Diameter of conductors (mm) | Number of conductors | Maximum allowable radius | Operating temperature range | Installation temperature range |
---|---|---|---|---|
0.9 | 1x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 3x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 5x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 7x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 10x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 14x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 20x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 30x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
0.9 | 40x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 1x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 3x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 5x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 7x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 10x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 14x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 20x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 30x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
1.4 | 40x4 | un-armoured 7.5 x Ø cable armoured 10 x Ø cable | -40° C to +60° C | -10° C to +60° C |
Reference: A-2Y(L)2YB2Y_H45 (01.HP_A-2Y(L)2YB2Y_H45_e)
Description
Cables from 1 to 40 quads of 0.9 or 1.4 mm, polyethylene insulated. Quads are stranded in layers to form the core which is then protected by a (L)2YB2Y anti rodent sheath. For installation in ducts or directly buried. Generally according to DB AG 416.0116 and DB AG 416.0115
They are used as control cables up to 90 kHz signals, especially in rail infrastructures, when protection is required against rodents.