Kabel A-2Y(L)2YB2Y_H45
Durchmesser der Leiter (mm) | Anzahl Leiter | Nenngewicht (kg/km) | Nenn-Außendurchmesser (mm) |
---|---|---|---|
0.9 | 1x4 | 12,3 | 177 |
0.9 | 3x4 | 17,3 | 320 |
0.9 | 5x4 | 19,7 | 420 |
0.9 | 7x4 | 21 | 506 |
0.9 | 10x4 | 25.5 | 675 |
0.9 | 14x4 | 27.4 | 828 |
0.9 | 20x4 | 30.1 | 1060 |
0.9 | 30x4 | 36.7 | 1492 |
0.9 | 40x4 | 39.2 | 1840 |
1.4 | 1x4 | 14.2 | 249 |
1.4 | 3x4 | 21.5 | 510 |
1.4 | 5x4 | 24.9 | 707 |
1.4 | 7x4 | 27 | 892 |
1.4 | 10x4 | 33.9 | 1241 |
1.4 | 14x4 | 36.5 | 1570 |
1.4 | 20x4 | 40.2 | 2060 |
1.4 | 30x4 | 49.5 | 2953 |
1.4 | 40x4 | 53.2 | 3729 |
Durchmesser der Leiter (mm) | Anzahl Leiter | Maximal zulässiger Radius | Betriebstemperaturbereich | Installationstemperaturbereich |
---|---|---|---|---|
0.9 | 1x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 3x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 5x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 7x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 10x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 14x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 20x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 30x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
0.9 | 40x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 1x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 3x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 5x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 7x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 10x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 14x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 20x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 30x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
1.4 | 40x4 | ungepanzert 7.5 x Ø kabel gepanzert 10 x Ø kabel | -40° C a +60° C | -10° C a +60° C |
Referenz: A-2Y(L)2YB2Y_H45 (01.HP_A-2Y(L)2YB2Y_H45_e)
Beschreibung
Kabel von 1 bis 40 Quads von 0,9 oder 1,4 mm, Polyethylen isoliert. Die Quads werden schichtweise verseilt, um den Kern zu bilden, der dann durch eine (L)2YB2Y-Anti-Nager-Hülle geschützt wird. Sie werden als Steuerkabel für Signale bis zu 90 kHz verwendet, insbesondere in der Eisenbahninfrastruktur, wenn ein Schutz gegen Nagetiere erforderlich ist. Zur Installation in Kanälen oder direkt unter der Erde.
Allgemein nach DB AG 416.0116 und DB AG 416.0115
Sie werden als Steuerkabel für Signale bis zu 90 kHz verwendet, insbesondere in der Eisenbahninfrastruktur, wenn ein Schutz gegen Nagetiere erforderlich ist.