Central Tube KSP

FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm)
2 1 81 9,3
4 1 81 9,3
6 1 81 9,3
8 1 81 9,3
12 1 81 9,3
16 1 91 9,9
24 1 91 9,9
FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm) Maximum tensile strength MAT (N) Impact resistence Curvature Crush resistance Thermal cycle Water penetration Jacket Thickness / FRP Diam (mm)
2 1 81 9,3 2700 N (εf<0.5%) 5 J D=20 x Ø cable, ∆α<0.05 dB 1500 N, 10 cm -20ºC / 60ºC, ∆α<0.05 dB LPwater ≤ 3 m (24 hours)
4 1 81 9,3 2700 N 5 J D=20 x Ø cable, ∆α<0.05 dB 1500 N, 10 cm -20ºC / 60ºC, ∆α<0.05 dB LPwater ≤ 3 m (24 hours)
6 1 81 9,3 2700 N 5 J D=20 x Ø cable, ∆α<0.05 dB 1500 N, 10 cm -20ºC / 60ºC, ∆α<0.05 dB LPwater ≤ 3 m (24 hours)
8 1 81 9,3 2700 N 5 J D=20 x Ø cable, ∆α<0.05 dB 1500 N, 10 cm -20ºC / 60ºC, ∆α<0.05 dB LPwater ≤ 3 m (24 hours)
12 1 81 9,3 2700 N 5 J D=20 x Ø cable, ∆α<0.05 dB 1500 N, 10 cm -20ºC / 60ºC, ∆α<0.05 dB LPwater ≤ 3 m (24 hours)
16 1 91 9,9 2800 N 5 J D=20 x Ø cable, ∆α<0.05 dB 1500 N, 10 cm -20ºC / 60ºC, ∆α<0.05 dB LPwater ≤ 3 m (24 hours)
24 1 91 9,9 2800 N 5 J D=20 x Ø cable, ∆α<0.05 dB 1500 N, 10 cm -20ºC / 60ºC, ∆α<0.05 dB LPwater ≤ 3 m (24 hours)

Referencia: KSP (66. HP_KSP_i)

Description

“Central tube” type fibre-optic cables with aramid yarns, armoured with a steel tape for mechanical and rodent protection and polyethylene sheath. 

This cable can be used for aerial lines, facades or can also be installed in ducts.