Cable A-D(ZN)2Y_10_6_CT
FO No. | No. Micromodules/Tubes | Weight (kg/km) | Nominal OD (mm) |
---|---|---|---|
4 | 1 | 11 | 3,7 |
6 | 1 | 11 | 3,7 |
12 | 1 | 15 | 4,1 |
24 | 1 | 15 | 4,1 |
FO No. | No. Micromodules/Tubes | Weight (kg/km) | Nominal OD (mm) | Maximum tensile strength MAT (N) | Impact resistence | Curvature | Crush resistance | Thermal cycle | Water penetration | Jacket Thickness / FRP Diam (mm) |
---|---|---|---|---|---|---|---|---|---|---|
4 | 1 | 11 | 3,7 | 250 N | 1 J | Ø =10 x ø cable; 4 turns; 3 cycles | 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) | -20 °C / 70 °C; ∆α < 0.1 dB/km | LP water ≤ 3 m (24 hours); No leakage | |
6 | 1 | 11 | 3,7 | 250 N | 1 J | Ø =10 x ø cable; 4 turns; 3 cycles | 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) | -20 °C / 70 °C; ∆α < 0.1 dB/km | LP water ≤ 3 m (24 hours); No leakage | |
12 | 1 | 15 | 4,1 | 250 N | 1 J | Ø =10 x ø cable; 4 turns; 3 cycles | 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) | -20 °C / 70 °C; ∆α < 0.1 dB/km | LP water ≤ 3 m (24 hours); No leakage | |
24 | 1 | 15 | 4,1 | 250 N | 1 J | Ø =10 x ø cable; 4 turns; 3 cycles | 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) | -20 °C / 70 °C; ∆α < 0.1 dB/km | LP water ≤ 3 m (24 hours); No leakage |
Referencia: 2021100035_A-D(ZN)2Y_10_6_CT(35.HP_2021100035_A-D(ZN)2Y_10_6_CT_i)
Description
Micro optic-fibre cables designed to be rapidly installed by blowing in micro-ducts De/Di 10/6 mm.
Cables used for medium or long distance telecommunications networks and designed with single mode type ITU-T G652D or G657A1.