Cable A-D(ZN)2Y_10_6_CT

FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm)
4 1 11 3,7
6 1 11 3,7
12 1 15 4,1
24 1 15 4,1
FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm) Maximum tensile strength MAT (N) Impact resistence Curvature Crush resistance Thermal cycle Water penetration Jacket Thickness / FRP Diam (mm)
4 1 11 3,7 250 N 1 J Ø =10 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
6 1 11 3,7 250 N 1 J Ø =10 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
12 1 15 4,1 250 N 1 J Ø =10 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
24 1 15 4,1 250 N 1 J Ø =10 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 1 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage

Referencia: 2021100035_A-D(ZN)2Y_10_6_CT(35.HP_2021100035_A-D(ZN)2Y_10_6_CT_i)

Description

Micro optic-fibre cables designed to be rapidly installed by blowing in micro-ducts De/Di 10/6 mm.

Cables used for medium or long distance telecommunications networks and designed with single mode type ITU-T G652D or G657A1.