Cable A-DQ2Y_12xn_LT

FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm)
12 1+5 26 5,4
24 2+4 25 5,4
48 4+2 25 5,4
72 6+0 24 5,4
96 8+0 35 6,3
144 12+0 55 8
192 1st layer 8+0 2nd layer 8+6 70 8,8
288 1st layer 9+0 2nd layer 15+0 76 9,3
FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm) Maximum tensile strength MAT (N) Impact resistence Curvature Crush resistance Thermal cycle Water penetration Jacket Thickness / FRP Diam (mm)
12 1+5 26 5,4 500 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
24 2+4 25 5,4 500 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
48 4+2 25 5,4 500 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
72 6+0 24 5,4 500 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
96 8+0 35 6,3 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
144 12+0 55 8 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
192 1st layer 8+0 2nd layer 8+6 70 8,8 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage
288 1st layer 9+0 2nd layer 15+0 76 9,3 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -15 °C / 70 °C; ∆α < 0.1 dB/km LP water ≤ 3 m (24 hours); No leakage

Referencia: 2021100035_A-DQ2Y_12xn_LT(37.HP_2021100035_A-DQ2Y_12xn_LT_i)

Description

Mini optic-fibre cables designed to be installed by blowing in micro-ducts.

Cables used for medium or long distance telecommunications networks and designed with single mode type ITU-T G652D or G657A1.