Cable A-DQ2Y_12xn_G657A1_200um_LT

FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm)
12 1+5 19 4,5
24 2+4 19 4,5
48 4+2 19 4,5
72 6+0 19 4,5
96 8,00 28 5,2
144 12+0 45 6,8
192 1st layer 8+0 2nd layer 8+6 56 7,7
288 1st layer 9+0 2nd layer 15+0 63 8
FO No. No. Micromodules/Tubes Weight (kg/km) Nominal OD (mm) Maximum tensile strength MAT (N) Impact resistence Curvature Crush resistance Thermal cycle Water penetration Jacket Thickness / FRP Diam (mm)
12 1+5 19 4,5 200 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K61 LP water ≤ 3 m (24 hours); No leakage
24 2+4 19 4,5 200 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K62 LP water ≤ 3 m (24 hours); No leakage
48 4+2 19 4,5 200 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K63 LP water ≤ 3 m (24 hours); No leakage
72 6+0 19 4,5 200 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K64 LP water ≤ 3 m (24 hours); No leakage
96 8,00 28 5,2 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K65 LP water ≤ 3 m (24 hours); No leakage
144 12+0 45 6,8 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K66 LP water ≤ 3 m (24 hours); No leakage
192 1ª capa 8+0 2ª capa 8+6 56 7,7 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K67 LP water ≤ 3 m (24 hours); No leakage
288 1ª capa 9+0 2ª capa 15+0 63 8 1000 N 2 J R : 20 x ø cable; 4 turns; 3 cycles 300 N/10 cm; 15 min; 3 positions (500mm apart) ∆α reversible (∆α ≤ 0.1 dB/km after test) -20 °C / 70 °C; ∆α < 0.1 dB/km K68 LP water ≤ 3 m (24 hours); No leakage

Referencia: 2021100035_A-DQ2Y_12xn_G657A1_200um_LT (36.HP_2021100035_A-DQ2Y_12xn_G657A1_200um_LT_i)

Description

Mini optic-fibre cables designed to be installed by blowing in micro-ducts.

Cables used for medium or long distance telecommunications networks and designed with single mode type ITU-T G657A1 200μm.